hhdb数据库介绍(9-26)

news/2024/11/29 11:24:12/文章来源:https://www.cnblogs.com/henghuixinda/p/18576210

计算节点参数说明

masterSourceInitWaitTimeout

参数说明:

Property Value
参数值 masterSourceInitWaitTimeout
是否可见
参数说明 启动时数据节点中主存储节点初始化超时时间
默认值 300
最小值 0
最大值 600
Reload是否生效

参数作用:
启动时,主存储节点在首次初始化失败后,会一直重连;若存在备存储节点且超过主存储节点初始化超时时间,则会切换到可用的备存储节点,若该节点所有存储节点都初始化失败,则整个节点不可用。如果数据节点初始化失败且无可用逻辑库,或数据节点下无存储节点,则计算节点无法启动。

2018-05-28 18:07:29.719 [WARN] [INIT] [main] r(-1) -- failed in connecting datasource:[id:182,nodeId:11 192.168.220.101:3306/db01 status:1,charset:utf8], exception:...省略...
The last packet sent successfully to the server was 0 milliseconds ago. The driver has not received any packets from the sever.
2018-05-28 18:07:31.719 [INFO] [INIT] [main] b(-1) -- try reinit datasource:[id:182,nodeId:11 192.168.220.101:3306/db01 status:1,charset:utf8]

引起存储节点超时的原因有:超出系统或者数据库连接限制、存储节点用户密码认证失败、网络延迟过大等。

maxAllowedPacket

参数说明:

Property Value
参数值 maxAllowedPacket
是否可见
参数说明 接收最大数据包限制
默认值 65536(KB)
最小值 1
最大值 1048576
Reload是否生效

参数作用:
控制前端连接发送的包大小。默认64M,当发送SQL语句的大小超过默认值64M时,计算节点会给出提示(Get a packet bigger than 'max_allowed_packet')。

ERROR 1153 (HY000): Get a packet bigger than 'max allowed packet'

同时,show variables能够显示配置的值。

mysql> show variables like '%allowed%;
+--------------------+----------+
| variable_name      | value    |
+--------------------+----------+
| max_allowed_packet | 16777216 |
+--------------------+----------+

maxCalciteScanSize

参数说明:

Property Value
参数值 maxCalciteScanSize
是否可见
参数说明 由Calcite执行的SQL中单表最大扫描行数
默认值 1000000
最小值 0
最大值
Reload是否生效

参数设置:

<property name="maxCalciteScanSize">1000000</property><!-- 由Calcite执行的SQL中单表最大扫描行数,0为不限制,默认1000000(maximum number of rows scanned in a single table in SQL executed by Calcite, value 0 means unlimited, default value is 1000000)-->

参数作用:
此参数用于控制Calcite逻辑单表抽取行数,当Calcite逻辑单表抽取行数大于maxCalciteScanSize参数设置数值时,会禁止SQL执行,并在会话中提示“unsupported statement”,与此同时,在hotdb.log日志内提示

Calcite scanned too many rows(XX> maxCalciteScanSize:XX) for table [XX] with where [] for connection

参数示例:

在未添加maxCalciteScanSize参数时,使用Calcite算法的SQL可以正常执行并返回结果:

root@127.0.0.1:hotdb 8.0.32 02:48:28> select avg(p3.id+p2.id) from zjj_sel_p2 as p2 left join zjj_sel_p3 as p3 on p2.id=p3.id;
+------------------+
| avg(p3.id+p2.id) |
+------------------+
|              532 |
+------------------+
1 row in set (4.24 sec)

与此同时,在hotdb.log日志内可见相关提示:

2023-03-31 14:48:48.087 [INFO] [CALCITE] [Labor-3] cn.hotpu.hotdb.calcite.CalciteClient() - [SELECT AVG(p3.id + p2.id) FROM zjj_sel_p2 AS `p2` LEFT JOIN zjj_sel_p3 AS `p3` ON p2.id = p3.id] executed in calcite successfully for [thread=Labor-3,id=1,user=root,host=127.0.0.1,port=3323,localport=42412,schema=HOTDB,isEtl=false,closed=false,[{_pid:7286}, {_platform:x86_64}, {_os:Linux}, {_client_name:libmysql}, {os_user:root}, {_client_version:8.0.32}, {program_name:mysql}]]

在添加maxCalciteScanSize参数并设置参数值为3后,在管理端口执行reload或重启计算节点,使用Calcite算法的SQL若Calcite逻辑单表抽取行数大于maxCalciteScanSize参数值时,则会禁止该SQL执行:

root@127.0.0.1:hotdb 8.0.32 02:51:55> select avg(p3.id+p2.id) from zjj_sel_p2 as p2 left join zjj_sel_p3 as p3 on p2.id=p3.id;
ERROR 10010 (HY000): unsupported statement for multi-table join in single avg expression

与此同时,在hotdb.log日志内可见相关提示:

2023-03-31 14:52:00.749 [INFO] [INNER] [Labor-4] cn.hotpu.hotdb.calcite.CalciteEnumerator() - Calcite scanned too many rows(20> maxCalciteScanSize:3) for table [HOTDB.ZJJ_SEL_P3] with where [] for connection:[thread=Labor-4,id=1,user=root,host=127.0.0.1,port=3323,localport=43012,schema=HOTDB,isEtl=false,closed=false,[{_pid:7286}, {_platform:x86_64}, {_os:Linux}, {_client_name:libmysql}, {os_user:root}, {_client_version:8.0.32}, {program_name:mysql}]], current SQL:select avg(p3.id+p2.id) from zjj_sel_p2 as p2 left join zjj_sel_p3 as p3 on p2.id=p3.id, session:AutoCommitTransactionSession in [thread=Labor-4,id=1,user=root,host=127.0.0.1,port=3323,localport=43012,schema=HOTDB,isEtl=false,closed=false,[{_pid:7286}, {_platform:x86_64}, {_os:Linux}, {_client_name:libmysql}, {os_user:root}, {_client_version:8.0.32}, {program_name:mysql}]]

maxConnections & maxUserConnections

参数说明:

Property Value
参数值 maxConnections
是否可见
参数说明 前端最大连接数
默认值 5000
最大值 300000
最小值 1
Reload是否生效
Property Value
参数值 maxUserConnections
是否可见
参数说明 用户前端最大连接数, 0为不限制
默认值 0
最大值 300000
最小值 0
Reload是否生效

参数作用:
计算节点支持限制前端连接数功能,出现访问过载时可辅助限制流量。

maxConnections是前端连接的最大连接数,是计算节点所允许的同时前端数据库连接数的上限。用户可以根据实际需要设置maxConnections,适当调整该值,不建议盲目提高设值。

maxUserConnections是同一个账号能够同时连接到计算节点的最大连接数。用户前端最大连接数可以为空,为空时默认给0即不限制用户连接数,此时以前端最大连接数为准。

当连接数大于所设置的值时,创建前端连接会有如下提示:

root> mysql -uzy -pzy -h127.0.0.1 -P9993Warning: Using a password on the command line interface can be insecure.
ERROR 1040 (HY000): too many connections

可以通过在服务端口set修改maxConnections和maxUserConnections的值,参数为GLOBAL级别:

mysql> set global max_connections = 5000;
Query OK, 0 rows affected (0.00 sec)mysql> show variables like '%max_connections%;
+-----------------+-------+
| variable_name   | value |
+-----------------+-------+
| max_connections | 5000  |
+-----------------+-------+mysql> set global max_user_connections = 1000;
Query OK, 0 rows affected (0.00 sec)mysql> show variables like '%max_user_connections%;
+----------------------+-------+
| variable_name        | value |
+----------------------+-------+
| max_user_connections | 1000  |
+----------------------+-------+

maxIdleTransactionTimeout

参数说明:

Property Value
参数值 maxIdleTransactionTimeout
是否可见
参数说明 未提交的空闲事务超时时间(ms)
默认值 86400000
最小值 0
最大值 172800000
Reload是否生效

参数设置:

<property name="maxIdleTransactionTimeout">864000000</property>

maxIdleTransactionTimeout参数默认值为86400000毫秒,即24小时,表示事务内最后一次SQL完成后超过24小时未提交事务,则判定为超时事务,计算节点在hotdb.log中以[INFO] [WATCHDOG] WatchDogLongTransactionCheckHandler标签记录连接IP、端口、用户名、逻辑库、lastsql、是否autocommit、后端连接的innodb_trx等信息,并关闭连接,自动回滚事务。

参数仅在enableWatchdog=true时生效。Watchdog中maxIdleTransactionTimeout每10分钟检测一次,在Watchdog对maxIdleTransactionTimeout的检测中判断连接的事务空闲时间,如果超出设定的阈值,则关闭连接;故实际的事务空闲时间不等于设定的阈值。

例如,事务空闲时间超出设定的阈值,将关闭连接,此时查看日志:

2019-07-01 18:09:24.528 [INFO] [WATCHDOG] [$NIOREACTOR-20-RW] cn.hotpu.hotdb.mysql.nio.handler.WatchDogLongTransactionCheckHandler(123) - Session [thread=Thread-13,id=1,user=ztm,host=127.0.0.1,port=3323,localport=46138,schema=PM] has not been queryed for 593s. executed IUDs:[UPDATE customer_auto_1 SET city = 'xxxx' WHERE id = 1]. binded connection:[MySQLConnection [node=2, id=59, threadId=14921, state=borrowed, closed=false, autocommit=false, host=10.10.0.202, port=3307, database=db_test251, localPort=52736, isClose:false, toBeClose:false] lastSQL:SET autocommit=0;UPDATE customer_auto_1 SET city = 'xxxx' WHERE id = 1]. innodb_trx:[(ds:2 trx_id:3435056156 trx_state:RUNNING trx_started:2019-07-01 17:59:33 trx_requested_lock_id:NULL trx_wait_started:NULL trx_weight:3 trx_mysql_thread_id:14921 trx_query:NULL trx_operation_state:NULL trx_tables_in_use:0 trx_tables_locked:1 trx_lock_structs:2 trx_lock_memory_bytes:1136 trx_rows_locked:1 trx_rows_modified:1 trx_concurrency_tickets:0 trx_isolation_level:REPEATABLE READ trx_unique_checks:1 trx_foreign_key_checks:1 trx_last_foreign_key_error:NULL trx_adaptive_hash_latched:0 trx_adaptive_hash_timeout:0 trx_is_read_only:0 trx_autocommit_non_locking:0 )]. we will close this session now.

maxJoinSize

参数说明:

Property Value
参数值 maxJoinSize
是否可见
参数说明 JOIN中间结果集行数限制(M:百万,K:千)
默认值 10M
最小值 1K
最大值 1000M
Reload是否生效

参数作用:
JOIN中间结果集允许执行的最大行数。中间结果集的计算方法:当SQL语句中没有条件时,计算笛卡尔积;当SQL语句中有条件时,计算符合join条件的行数。

当JOIN中间结果集大于设置的行数时,会提示如下信息:

mysql> select * from customer_auto_1 a join customer_auto_3 b on a.postcode=b.postcode;ERROR 1104 (HY000): The SELECT would examine more than MAX_JOIN_SIZE rows; check your maxJoinSize in server.xml

可通过set session max_join_size修改当前会话参数值,使JOIN中间结果集在1~ 2124000000之间:

mysql> show variables like '%max_join_size%;
+---------------+-------+
| variable_name | value |
+---------------+-------+
| max_join_size | 5000  |
+---------------+-------+mysql> set global max_user_connections = 1000;
Query OK, 0 rows affected (0.00 sec)mysql> show variables like '%max_user_connections%;
+----------------------+------------+
| variable_name        | value      |
+----------------------+------------+
| max_user_connections | 2124000000 |
+----------------------+------------+mysql> set session max_join_size=1;
Query OK, 0 rows affected (0.00 sec)mysql> show variables like '%max_user_connections%;
+----------------------+-------+
| variable_name        | value |
+----------------------+-------+
| max_user_connections | 1     |
+----------------------+-------+mysql> select * from bn_a_jwy a join bn_c_jwy b on a.a=b.a where a.a='d';
ERROR 1104 (HY000): The SELECT would examine more than MAX_JOIN_SIZE rows; check your maxJoinSize in server.xml

maxLatencyForRWSplit

参数说明:

Property Value
参数值 maxLatencyForRWSplit
是否可见
参数说明 读写分离中可读从库最大延迟
默认值 1000ms
最小值 200
最大值 10000
Reload是否生效

参数作用:
开启读写分离后,主从延迟小于设置的延迟时间时,读从库:

mysql> select * from cd;
+----+-------+
| id | name  |
+----+-------+
| 1  | slave |
| 2  | slave |
| 3  | slave |
| 4  | slave |
| 5  | slave |
+----+-------+
5 rows in set (0.00 sec)

开启读写分离后,当可读从库的延迟超过设置的时间后,会读主库:

mysql> select * from cd;
+----+--------+
| id | name   |
+----+--------+
| 1  | master |
| 2  | master |
| 3  | master |
| 4  | master |
| 5  | master |
+----+--------+
5 rows in set (0.00 sec)

maxNotInSubquery

参数说明:

Property Value
参数值 maxNotInSubquery
是否可见 隐藏不显示
参数说明 子查询中最大not in个数
默认值 20000
Reload是否生效

参数设置:
server.xml中maxNotInSubquery参数配置 如下配置:

<property name="maxNotInSubquery">20000</property><!--子查询中最大not in个数 -->

参数作用:
控制子查询中最大NOT IN个数,默认20000,当执行的SQL语句中NOT IN子查询为分片表且带有聚合函数,此时去重后的NOT IN个数超过默认值20000时,计算节点会限制该SQL执行,并给出ERROR提示

(ERROR 1104 (HY000): The sub SELECT would examine more than maxNotInSubquery rows; check your maxNotInSubquery in server.xml)

例如:(为方便测试,设置maxNotInSubquery 为10)

mysql> use pm
Database changedmysql> show tables;
+------------------+
| Tables_in_PM     |
+------------------+
| customer_quan_2  |
| customer_route_1 |
| customer_route_2 |
+------------------+
3 rows in set (0.00 sec)mysql> select * from customer_route_2 a where a.postcode not in (select postcode from customer_route_1 b where b.id > 205119 limit 20);
ERROR 1104 (HY000): The sub SELECT would examine more than maxNotInSubquery rows; check your maxNotInSubquery in server.xml

日志中会以[INFO] [SQL]标签记录对应信息

2019-10-08 14:33:41.725 [INFO] [SQL] [$NIOExecutor-3-2] cn.hotpu.hotdb.j.h(2626) - unsupported subquery:[thread=$NIOExecutor-3-2,id=152197,user=ztm,host=127.0.0.1,port=3323,localport=49458,schema=PM] AutoCommitTransactionSession in [thread=$NIOExecutor-3-2,id=152197,user=ztm,host=127.0.0.1,port=3323,localport=49458,schema=PM], sql:select * from customer_route_2 a where a.postcode not in (select postcode from customer_route_1 b where b.id > 205119 limit 20), error code:1104, error msg:The sub SELECT would examine more than maxNotInSubquery rows; check your maxNotInSubquery in server.xml

同时,在日志和3325端口show @@systemconfig能够查看配置的值,该参数在修改后可reload生效。

mysql> show @@systemconfig;config | {[enableFlowControl](#enableFlowControl):"true",[recordSql](#recordSql):"false",[defaultMaxLimit](#defaultMaxLimit):"10000","bakPassword":"hotdb_config","bakUrl":"jdbc:mysql://192.168.220.138:3306/hotdb_config_249ha","managerPort":"3325","heartbeatPeriod":"2",[cryptMandatory](#cryptMandatory):"false","password":"hotdb_config",[enableCursor](#enableCursor):"false","username":"hotdb_config",[enableXA](#enableXA):"false",[errorsPermittedInTransaction](#errorsPermittedInTransaction):"true",[strategyForRWSplit](#strategyForRWSplit):"0",[enableWatchdog](#enableWatchdog):"false","haNodeHost":"192.168.220.139:3325",[maxJoinSize](#maxJoinSize):"9148M",[maxNotInSubquery](#maxNotInSubquery):"10",[pingLogCleanPeriodUnit](#pingLogCleanPeriodUnit):"0",[clientFoundRows](#clientFoundRows):"false",[joinCacheSize](#joinCacheSize):"236","enableHeartbeat":"true","url":"jdbc:mysql://192.168.220.138:3306/hotdb_config_249ha",[parkPeriod](#parkPeriod):"100000",[maxSqlRecordLength](#maxSqlRecordLength):"4000",[joinBatchSize](#joinBatchSize):"46000",[enableSubquery](#enableSubquery):"true","heartbeatTimeoutMs":"500",[pingPeriod](#pingPeriod):"300",[joinLoopSize](#joinLoopSize):"18500","VIP":"192.168.220.171",[joinable](#joinable):"true","maxUserConnections":"4900",[pingLogCleanPeriod](#pingLogCleanPeriod):"1",[dataNodeIdleCheckPeriod](#dataNodeIdleCheckPeriod):"120",[deadlockCheckPeriod](#deadlockCheckPeriod):"3000",[sqlTimeout](#sqlTimeout):"3600","bakUsername":"hotdb_config","enableLatencyCheck":"true",[waitSyncFinishAtStartup](#waitSyncFinishAtStartup):"true","checkVIPPeriod":"500",[statisticsUpdatePeriod](#statisticsUpdatePeriod):"0",[usingAIO](#usingAIO):"0",[showAllAffectedRowsInGlobalTable](#showAllAffectedRowsInGlobalTable):"false",[maxLatencyForRWSplit](#maxLatencyForRWSplit):"1000","maxConnections":"5000",[enableSleep](#enableSleep):"false",[waitForSlaveInFailover](#waitForSlaveInFailover):"true",[autoIncrement](#autoIncrement):"true",[processorExecutor](#processorExecutor):"4",[highCostSqlConcurrency](#highCostSqlConcurrency):"400","latencyCheckPeriod":"500","processors":"16",[weightForSlaveRWSplit](#weightForSlaveRWSplit):"50","haState":"master",[readOnly](#readOnly):"false",[timerExecutor](#timerExecutor):"4","serverPort":"3323",[frontWriteBlockTimeout](#frontWriteBlockTimeout):"10000",[switchoverTimeoutForTrans](#switchoverTimeoutForTrans):"3000"}
1 row in set (0.01 sec)

maxReconnectConfigDBTimes

参数说明:

Property Value
参数值 maxReconnectConfigDBTimes
是否可见
参数说明 最大重试连接配置库次数
默认值 3
最大值 1000
最小值 0
Reload是否生效

参数设置:
server.xml中maxReconnectConfigDBTimes参数如下配置:

<property name=" maxReconnectConfigDBTimes ">3</property><!-- 最大重试连接配置库次数 -->

参数作用:
防止计算节点启动、HA切换或reload时配置库连接耗时过长,增加配置库重连次数。超过最大重试连接次数(重连耗时默认是3*2s),会自动切换到从配置库连接。

maxSqlRecordLength

参数说明:

Property Value
参数值 maxSqlRecordLength
是否可见
参数说明 SQL执行统计中SQL语句记录的最大长度
默认值 1000
最小值 1000
最大值 16000
Reload是否生效

参数作用:
该参数是指操作日志智能分析中的SQL纪录时的最大长度。

执行的SQL语句超过设置的长度后,会自动截取,用省略号...代替,如下图所示:
在这里插入图片描述

maxFlowControl

参数说明:

Property Value
参数值 maxFlowControl
是否可见
参数说明 各存储节点流控限制上限
默认值 256
Reload是否生效

参数设置:
server.xml的maxFlowControl参数设置为256

<property name="maxFlowControl">256</property><!-- 各数据源流控限制上限[32,1024](Maximum concurrency limit(between 32 and 1024) for flow control in each datasource) -->

参数作用:
在开启存储节点限流时,控制后端各存储节点单次最大并发个数,以免因流量过大而导致存储节点服务异常

maxLatencyForReadOnly

参数说明:

Property Value
参数值 maxLatencyForReadOnly
是否可见
参数说明 开启实例级别只读后,可读从库允许的最大延迟时间
默认值 1000(ms)
最小值 200
最大值 10000
Reload是否生效

参数设置:
server.xml中maxLatencyForReadOnly参数配置:

<property name="maxLatencyForReadOnly">4000</property><!-- 只读实例从库最大延迟(ms)(Maximum delay of readable Standby Slave in instance readonly ) -->

参数作用
控制开启实例级别只读后,可读从库允许的最大延迟时间:单机房内复制延迟超过该参数设置的值开始读其他可用从机或主机(先读其他可用从机,无可用从机时读主机),灾备模式下的灾备机房,复制延迟超过该参数设置的值开始拒绝读取。

如:主从数据节点下,maxLatencyForReadOnly设置值为4000,从库的复制延迟大于4000ms,此时只读计算节点的读操作发往主库;若小于4000ms则读操作发往优先级最高的从库。

root@192.168.210.135:(none) 8.0.30 05:00:06> show @@latency;
+------+---------------------------+---------------------------+---------+
| dn | info        | backup_info     | latency |
+------+---------------------------+---------------------------+---------+
| 20 | 192.168.210.136:3311/db01| 192.168.210.54:3308/db01 | 5011 ms |
+------+---------------------------+---------------------------+---------+
1 rows in set (0.02 sec)

灾备模式下灾备机房的只读计算节点超出maxLatencyForReadOnly设置的值时拒绝读取。

root@192.168.210.136:hotdb 8.0.30 06:44:09> select count(*) from test75;
ERROR 10185 (HY000): Datasource&apos;s lantecy is too big

maxCachedTrxIud

参数说明:

Property Value
参数值 maxCachedTrxIud
是否可见
参数说明 缓存供日志输出的事务中执行的IUD语句的最大数量
默认值 100
最小值 0
最大值 1000
Reload是否生效

参数设置:

<property name="maxCachedTrxIud">100</property><!-- 缓存供日志输出的事务中执行的IUD语句的最大数量,默认100条(Maximum number of cached IUD statements in transaction for log, default 100.) -->

参数作用:
缓存需要输出日志的SQL场景,可通过该参数设置需要输出SQL的条数,方便问题排查定位。目前主要的场景有:事务异常、死锁检测、watchdog等。

设置maxCachedTrxIud的值为2,测试死锁场景,计算节点输出的死锁日志中,只输出了2条SQL
在这里插入图片描述
在这里插入图片描述

maxTempFileSize

参数说明:

Property Value
参数值 maxTempFileSize
是否可见
参数说明 连接堆外缓存数据的最大临时文件大小
默认值 100G
最小值 0
最大值 /
Reload是否生效

参数设置:

<property name="maxTempFileSize">100G</property><!-- 连接堆外缓存数据的最大临时文件大小,默认为100G(Max temporary file size for connection to cache data, default is 100G) -->

参数作用:
连接堆外缓存数据的最大临时文件大小,默认为100G。单位只能以G、M、K结尾。

maxMinorityElectionTimeoutMills

参数说明:

Property Value
参数值 maxMinorityElectionTimeoutMills
是否可见
参数说明 控制特定条件下计算节点自动下线不再发起选举的机制(ms)
默认值 0(不开启)
Reload是否生效

参数设置:

<property name="maxMinorityElectionTimeoutMills">0</property><!--控制特定条件下计算节点自动下线不再发起选举的机制(ms) -->

参数作用:
econdary计算节点发现primary心跳超时触发选举,如果这个计算节点收到的集群成员信息始终为少数节点,即小于((集群成员总数/2)+1),且在该参数超时前都未选举成功,则该计算节点自动下线,不再发起选举,默认0,不开启此机制。

例:A机房和B机房构成双活集群,A机房3个计算节点,B机房2个计算节点,primary节点在A机房。若AB机房之间网络故障,B中心的计算节点会不停发起选举,此参数合理配置可使B中心计算节点及时下线。

maxNumberForSelect

参数说明:

Property Value
参数值 maxNumberForSelect
是否可见
参数说明 SQL查询结果的数据最大返回条数
默认值 0
最小值 0
最大值 0
Reload是否生效

参数设置:

<property name="maxNumberForSelect">0</property><!-- 控制SQL查询语句返回的最大结果条数(为0代表不限制,最>大:1000)(The max number limits of results returned by SQL query, 0 for no limit, max: 1000) -->

参数作用:
控制SQL查询语句返回的最大结果条数(为0代表不限制)。

当maxNumberForSelect设置为5时,表示对于SQL查询语句返回的最大结果条数为5条。举例说明如下,对于一张有10行的数据的hotdb_t6表,查出来的结果仅有5行,并会给出warning的提示信息:

root@127.0.0.1(hotdb) 8.0.30 05:00:06> select count(*) from hotdb_t6;
+----------+
| count(*) |
+----------+
|       10 |
+----------+
1 row in set (0.03 sec)root@127.0.0.1(hotdb)  8.0.30 05:00:20> select * from hotdb_t6;
+---+----+-----+------+
| a | aa | aaa | aaaa |
+---+----+-----+------+
| 4 | 44 | d   | dd   |
| 5 | 55 | e   | ee   |
| 6 | 66 | a   | aa   |
| 7 | 77 | b   | bb   |
| 1 | 11 | a   | aa   |
+---+----+-----+------+
5 rows in set, 1 warning (0.01 sec)Warning (Code 10268): The query result exceeds the maxNumberForSelect parameter value and includes data that is not fully displayed

当maxNumberForSelect设置为0时,表示不对SQL查询语句返回的最大结果条数做任何限制。举例说明如下,对于一张有10行的数据的hotdb_t6表,查出来的结果会显示所有行数:

root@127.0.0.1(hotdb) 8.0.30 05:0030> select count(*) from hotdb_t6;
+----------+
| count(*) |
+----------+
|       10 |
+----------+
1 row in set (0.03 sec)root@127.0.0.1(hotdb)  8.0.30 05:00:40> select * from hotdb_t6;
+----+------+-----+------+
| a  | aa   | aaa | aaaa |
+----+------+-----+------+
|  4 |   44 | d   | dd   |
|  5 |   55 | e   | ee   |
|  6 |   66 | a   | aa   |
|  7 |   77 | b   | bb   |
|  1 |   11 | a   | aa   |
|  2 |   22 | b   | bb   |
|  3 |   33 | c   | cc   |
|  8 |   88 | c   | cc   |
|  9 |   99 | d   | dd   |
| 10 | 1010 | f   | ff   |
+----+------+-----+------+
10 rows in set (0.01 sec)

本文来自互联网用户投稿,该文观点仅代表作者本人,不代表本站立场。本站仅提供信息存储空间服务,不拥有所有权,不承担相关法律责任。如若转载,请注明出处:http://www.hqwc.cn/news/843345.html

如若内容造成侵权/违法违规/事实不符,请联系编程知识网进行投诉反馈email:809451989@qq.com,一经查实,立即删除!

相关文章

[TSDB] OpenGemini wal文件与tssp文件的用途与关系

前言 openGemini是一款面向物联网、车联网、工业互联网、运维监控等领域的开源分布式时序数据库。 在openGemini中,WAL(Write-Ahead Logging)文件和TSSP(Time Series Storage Protocol)文件扮演着重要的角色,以下是关于它们的用途及关系的详细解释: WAL文件 用途WAL文件…

hhdb数据库介绍(9-24)

计算节点参数说明 failoverAutoresetslave 参数说明:Property Value参数值 failoverAutoresetslave是否可见 是参数说明 故障切换时,是否自动重置主从复制关系默认值 falseReload是否生效 否参数设置: <property name="failoverAutoresetslave">false</p…

“4个应用场景”以图搜图与实物比对,赋能机械制造智能化升级

背景 随着制造业和工业生产的不断发展,机械设计和加工过程中的图纸与实物比对成为生产质量管控的重要环节。然而,传统手动比对方式耗时费力,且易出现误差。思通数科凭借自主研发的大模型技术,为用户提供了一套高效、智能的以图搜图与实物比对解决方案,大幅提升了机械设计和…

校园防欺凌ai语音监控系统

校园防欺凌ai语音监控系统核心优势在于其先进的音频识别算法,校园防欺凌ai语音监控系统能够识别出关键词如侮辱、恐吓、求救等敏感语言,并能够区分正常的交流和潜在的欺凌行为。系统通过安装在校园各关键区域的麦克风捕捉声音信号,这些信号会被实时传输到中央处理单元。在这…

hhdb数据库介绍(9-18)

SQL语法支持 计算节点语法特殊功能 默认分片规则建表 在使用关系集群数据库时,需要先将表的分片规则信息配置好之后才能创建表。实际使用过程中,用户可能对关系集群数据库及分片规则不了解,这就需要一种能直接过渡到HHDB Server的方案,该方案能根据逻辑库关联的分片节点数量…

Windows Cmd查询端口号对应的进程及关闭进程

Windows Cmd查询端口号对应的进程及关闭进程 1. 使用 netstat 查询端口和进程信息 运行以下命令: netstat -ano | findstr :端口号示例: 如果要查询端口 80812. 查找进程 ID 所属的程序 通过上面命令的输出获取到 PID(进程 ID)后,可以使用以下命令查看对应的程序名称: ta…

hhdb数据库介绍(9-16)

SQL语法支持 事务管理与锁语句语句类型 事务语句 语句参数 状态 说明事务管理 START TRANSACTION 无参数 支持WITH CONSISTENT SNAPSHOT 支持READ WRITE 支持READ ONLY 支持BEGIN支持COMMIT支持COMMIT [AND [NO] CHAIN] [[NO] RELEASE] 支持ROLLBACK支持ROLLBACK [AND [NO] CHA…

MySQL_索引失效_类型转换

1.类型转换索引失效场景SELECT * FROM tbl_name WHERE str_col=1; 列str_col上有建立索引,一个字符串类型的列给一个整数类型的值。 问题:为什么会导致索引失效? 原因:MySQL官方文档解释:The reason for this is that there are many different strings that may convert …

Thinkpad X1 Tablet gen2 键盘改USB

0 写在前面 前文Thinkpad X1 Tablet gen2 键盘固件逆向实现Ctrl与Fn换位记录了Thinkpad X1 Tablet gen2 键盘Fn和Ctrl换位的研究过程,本文记录一下该键盘改USB的过程。因为操作的时候没有留太多照片,所以尽量画图示意。 0.1 其他网友硬改成果 在硬改该键盘之前,在网上发现其…

2024年不同行业都适用的10款项目管理工具推荐,总有一款适合你!

在当今快节奏的商业环境中,项目管理工具的选择对于项目的成功至关重要。不同的行业和项目类型需要不同的工具来满足其特定的需求。本文将介绍10款适用于不同行业的项目管理工具,帮助您在2024年找到最适合您项目的解决方案。 禅道项目管理软件 禅道项目管理软件是一款开源的项…

多模态遥感技术:智慧城市更新与表达的新路径

随着智慧城市建设的不断深入,多模态航空遥感技术正成为推动城市智慧化的关键力量。多模态航空遥感通过集成多种传感器和数据源,提供了丰富的地表信息,极大地提升了城市空间数据的准确性和应用价值。多模态航空遥感技术多模态航空遥感技术利用多种传感器,如全色相机、多光谱…

H5-9 表格

1、表格展示效果表格在数据展示方便面非常简单,并且表现优秀 2、表格组成与特点 行、列、单元格 单元格特点:通行等高、同列等宽。 3、表格标签表格:<table>行:<tr>列:<td> <table><tr><td>1</td><td>1</td>&l…